NEW ITEMS IN THE PORTFOLIO OF PRESS GLASS ACOUSTIC GLAZED UNITS

, Glass & Glazing

PRESS GLASS continues the expansion of acoustic glazed units portfolio, meeting individual expectations of Customers seeking products with specific design and weighted sound reduction index.

“The direct reason for weighted sound reduction index tests of our panes are requirements and expectations of our customers, who usually seek a universal product, which is glass with good thermal insulation properties, protecting against overheating of building interior. They also seek protection against breaking and entering or accidental breaking, paired with acoustic insulation properties of specific glass. Very often, the critical consideration determining the possibility of submitting a bid for glazing works under specific project is having in the portfolio acoustic glass units with strictly defined minimum parameters” says Tomasz Ślusarek, Quality Specialist at PRESS GLASS.

PRESS GLASS portfolio has been recently expanded by two new items, featuring Rw index 45 and 48 dB.

Item Structure [mm] Rw [dB] C [dB] Ctr [dB]
1 10,8T (VSG 55.2T) Acoustic/16Ar/6/16Ar/8T 45 -2 -7
2 8,8T (VSG 44.2T) Acoustic/12Ar/6/12Ar/12.8T (VSG 66.2T) Acoustic 48 -3 -8

T – Thermofloat (glass with a thermal insulating layer)

Ar – Noble gas Argon

Now, company’s portfolio contains 88 types of acoustic glazed units.

PRESS GLASS notified also that they updated the test of one of their basic glazings, with the structure 4T/12Ar/4/12Ar/4T. The key parameter of this product, Rw, is now improved, and its value s 33dB.

Item Structure [mm] Rw [dB] C [dB] Ctr [dB]
1 4T/12Ar/4/12Ar/4T 33 -2 -5

All tests completed are confirmed by certificates issued by independent certification bodies. As indicated by Tomasz Ślusarek, acoustic properties of PRESS GLASS products are determined in testing laboratories with Notified Laboratory status.

“Due to the recent active presence of PRESS-GLASS on overseas markets, in addition to indices Rw, Ra and Ratr also relevant acoustic insulation coefficients acc. to American standards are determined. Those are Sound Transmission Class (STC) and Outdoor Indoor Transmission Class (OITC). Both parameters also refer to insulation from airborne sounds, although calculation method and noise frequency ranges adopted for calculations significantly differ from those adopted for their European equivalents” adds Tomasz Ślusarek.

For details of all 88 types of acoustic glass units see the configuration tool on the website:
http://www.pressglass.eu/market-offer/glazed-units/acoustic-glazed-units?lang=en

Get in touch









    Your Details will be passed to the companies you have expressed interest in only and no other parties